Repairing Your SwitcheOn Tanis PreHeat Remote

The tiny ceramic fuse.

If you have the popular Tanis PreHeat Remote, it’s likely you either have overloaded and blown its internal fuse, or will! Well, OK, maybe you’re more careful than I am, but in addition to preheat, I often use my Tanis outputs for other things, like the battery charger for my tug. And recently, I plugged in a motorized device with a startup surge current, and suddenly the Tanis PreHeat Remote was dead!

What to do? A removal of four screws and quick trace of the power input revealed an inline 15-amp fuse, which, of course, was blown. But it happens to be a soldered-in tiny ceramic fuse—hard to find and a pain to replace in the future. A simple solution revealed itself: Particularly if you have the two-output Tanis, the case has two knockouts for the additional outputs for the four-output version. I chose one of them, drilled it out to a half-inch for a standard 3AG panel-mount fuse holder, and installed the fuse holder with two short wires soldered to the PCB pads where the ceramic fuse was located. A 15-amp 3AG fuse finished the job off! Now, any future blown fuses can be replaced in a jiffy!

Fuse holder: Amazon, DigiKey

Fuse holder soldered to ceramic fuse pads.
Fuse holder installed in the drilled knockout.

Reinhard Metz
Reinhard Metz
Reinhard Metz built his Wheeler Express over an eight-year period and has been flying it for 27 years. He is a retired Bell Labs electrical engineer and had a second career managing engineering for a commercial food equipment company. Reinhard lives in Wheaton, Illinois, and flies out of DuPage County Airport.

SIGN UP FOR OUR NEWSLETTER

Latest
Related

5 COMMENTS

Subscribe to this comment thread
Notify of
guest
5 Comments
Oldest
Newest
Jeff S
Jeff S
1 month ago

Great tip! I love my SwitcheON combined with a Twin Hornet heater. Helps with flying thru Michigan winters in spite of having no doors on my hangar …

luckeyone
luckeyone
1 month ago

Just installed my SwitchOn and noticed the temperature display is always 10deg or more higher than the actual temperature. I assume the sensor is on the bread board in the box and is sensing the temp in the box. I plan on contacting SwitchON and seeing if that is the case. If so I am considering replacing with a remote sensor to give actual hanger temperature. After the warrantee is up…..

Dan Marotta
Dan Marotta
1 month ago

What’s a “SwitchOn”? Oh, never mind, I’ll look it up. I’ve used wifi activated outlets and an app on my phone but, now that I’ve sold my hangar and am moving into a rental without wifi, I’ll need to take a look.

Dan Marotta
Dan Marotta
Reply to  Dan Marotta
1 month ago

Well, given the purchase price, I’ll just turn on my heaters manually and have a cup of coffee while I wait. It rarely gets below about +20 deg F here in the NM desert and, on that rare day when it drops to -30 deg F, I’ll stay home and have another cup!

SwitcheOn
1 month ago

Nice mod. I would recommend slightly larger wire (14 awg or 16 awg) going to the fuse holder, but otherwise this is well done. Also, resist the temptation to put a larger fuse in there. The values were chosen to comply with electrical code and not start fires.